Online TOWER UPS Rhomo RM11-H SERIES 6-10KVA

The high-frequency Tower UPS RM31-H series UPS (Uninterruptible Power Supply) is a new generation of universal UPS newly designed and manufactured by Rhimo. Adopting a tower structure and an online, double-conversion architecture design, compared with online interactive or backup UPS models, it can provide users’ loads with a better power supply environment. The products are widely applicable to Class I load equipment in government agencies, financial institutions, radio, film and television departments, educational institutions, medical and health care units, small and medium-sized enterprises and institutions, etc.

POWER RANGE

6-10kva

POWER PHASE

1/1 phase

 

Category:

APPLICATION

It is suitable for office, communication, data machine room environments or other narrow spaces.

Features

  • Online double-conversion design and microprocessor control technology
  • Liquid crystal display for convenient operation and maintenance
  • Wide input voltage range (110Vac to 300Vac), adaptable to harsh power grid environments
  • Input power factor ≥ 0.99, designed as a green power supply
  • Output power factor of 1, with strong load-bearing capacity
  • Efficiency in mains mode is as high as over 94%, featuring high efficiency and energy conservation
  • The charging current of the long-lasting model reaches 12A, with multi-stage intelligent charging management
  • Complete protection mechanisms such as under-voltage, over-voltage, short-circuit, and over-temperature protection
  • RS232 interface and EPO interface are standard, and SNMP card and USB port are optional.

Bypass protection

• The bypass power supply function greatly enhances the emergency handling capacity of the UPS, protecting the user’s load equipment from the risk of power outage.

Pure Sine Wave Output

• Adopting the online double-conversion architecture and digital control technology, it can provide the best power supply guarantee for users’ load equipment with sinusoidal waves of low distortion degree, whether in the mains mode or the battery mode.

Zero Transfer Time

• Zero transfer time between utility and battery modes during power outages/restorations ensures uninterrupted load operation.

Green Power Design

• Equipped with input power factor correction (PFC), achieving a high power factor of ≥0.99 to minimize grid pollution and align with green power design principles.

Auto Restart Function

• Automatic restart when utility power resumes after outage, enabling unmanned operation without manual intervention.

Intelligent Battery Management

• It adopts multi-stage battery charging management technology, featuring a powerful charging capacity and supporting the configuration of large-capacity battery packs.

Generator Compatible

• With a wide range of input voltage and frequency, the UT11 series can be used in conjunction with branded generators to provide pure, safe and stable power supply for loads.

model :RM11-H RM11-6K-H RM11-6KL-H RM11-10K-H RM11-10KL-H
Capacity/Power 6KVA/6KW 10KVA/10KW
input Input Wiring L+N+PE
Rated Input Voltage 208/220/230/240VAC
Voltage Range 110~300VAC
Frequency Range 44~56Hzor 54Hz~66Hz
Input Power Factor ≥0.99
Output Wiring L+N+PE
Output Voltage 208/220/230/240VAC
output Voltage Regulation ±1%
Output Frequency Online mode: Follow the mains frequency. Battery mode: 50/60Hz±0.1%
Output Harmonic Distortion ≤3%(Linear Load) ≤5%(Non-linear Load)
Output Power Factor 1
Transfer Time Mains – battery: 0 ms. Inverter – bypass: 4 ms.
Overload Capacity Mains mode:
30min@102%~110%Load;10min@110%~130%Load;30s@130%~150%Load;200ms@>150%Load
Battery mode:
1min@102%~110%Load;10s@110%~130%Load;3s@130%~150%Load;200ms@>150% Load
Efficiency (mains supply mode) 95%
battery Battery Voltage Built-in 6x12V
7 AH/9AH battery
192-240vdc Built-in 6x12V
7 AH/9AH battery
192-240vdc
Charge Current 1A 1-12A(max) 1A 1-12A(max)
display interface Liquid crystal display interface, which supports operating mode/load/electric quantity/input/output, etc.
communication interface It is standardly equipped with an RS232 communication interface. SNMP smart cards and USB interfaces are optional.
Environment Operating Temperature 0~40°C
Operating Humidity No condensation at 20% – 95% (humidity level)
Altitude It should not exceed 1000m. Derating is required when it is above 1000m. The maximum altitude is 4000m. Refer to IEC62040.
size 190x454x700 190x454x322 190x454x700 190x454x322
weight 53.2/61.2 9.8 54.6/62.6 11.2
Scroll to Top